What are the methods for installing and wiring monochrome and colorful LED wall washers for night scene illumination? Let's explore them in this article.
No more than 16/12 fixtures should be connected in parallel. If exceeding 16/12 fixtures, please increase the power input line.
The total power of each branch must not exceed 80% of the total power of the power supply.
The total length of the power output trunk should not exceed 50 meters, with power supplied in the middle and distributed to the left and right.
Offline/online controllers are connected to sub-controllers using Cat 5e twisted pair cables, not exceeding 80 meters.
There are 8 output ports on the offline controller, each capable of handling 172 pixels.
Each output port can support 300 meters, including the length of the light fixture and the connecting cable.
No more than 16/12 fixtures should be connected in series. If exceeding 16/12 fixtures, please increase the power input wire (use a specialized 3-way connector).
The total power of each branch must not exceed 80% of the total power of the power supply.
The total length of the power output trunk should not exceed 50 meters, with power supplied in the middle and distributed to the left and right.